Emergency Support

Generator Down? Get Technical Fault Diagnosis and Repair Support.

When a generator fails, every minute matters. GMA PowerTech provides fault diagnosis and corrective support for no-start conditions, shutdown alarms, overheating, low oil pressure, unstable voltage, unstable frequency, ATS transfer failure, fuel problems, battery issues, and control faults. The response focuses on safe restoration, root cause identification, and clear recommendations to prevent repeated failure.

emergency_homeCall Emergency Dispatch: 0738 449 192

Common Generator Faults Supported

GMA PowerTech investigates and repairs the faults that facility teams encounter during stressful power-loss events.

Fault CategorySymptomsGMA Response
No-start / hard startGenerator cranks but does not start, does not crank, weak battery, start failure alarm.Battery/starter checks, fuel supply checks, controller alarms, sensor review, wiring and safety interlock checks.
Shutdown under loadStops when load is applied, overload, high temperature, low oil pressure, fuel starvation.Load review, cooling and lubrication checks, fuel system diagnosis, protection/alarm review.
Unstable voltageVoltage too high, too low, fluctuating, AVR alarm, sensitive equipment affected.AVR check, alternator sensing, excitation circuit, load balance, wiring inspection.
Unstable frequencyFrequency drops or rises, engine hunting, speed instability.Governor/speed control checks, fuel supply, load conditions, controller settings.
OverheatingHigh coolant temperature alarm, coolant loss, radiator blockage, fan problem, poor ventilation.Cooling system inspection, airflow review, radiator/fan checks, coolant and hose checks.
Fuel system faultAir in fuel, clogged filters, water contamination, transfer pump failure, low fuel pressure.Filter service, leak checks, tank/day tank inspection, pump and line checks.
ATS / transfer faultGenerator runs but load does not transfer, utility return issue, manual/auto issue.ATS control sequence test, interlock review, contactor/breaker checks, signal verification.
Control panel alarmSensor fault, emergency stop, communication loss, controller configuration issue.Alarm interpretation, wiring/sensor checks, controller settings, functional testing.
Low output / overloadGenerator cannot carry load, breaker trips, voltage collapse.Load measurement, phase balance, capacity review, breaker/protection and alternator checks.